There are 4 USB controllers on MT8195, the controllers (IP1~IP3, exclude IP0) have a wrong default SOF/ITP interval which is calculated from the frame counter clock 24Mhz by default, but in fact, the frame counter clock is 48Mhz, so we should set the accurate interval according to 48Mhz. Here add a new compatible for MT8195, it's also supported in driver. But the first controller (IP0) has no such issue, we prefer to use generic compatible, e.g. mt8192's compatible. Signed-off-by: Chunfeng Yun <chunfeng.yun@xxxxxxxxxxxx> --- Documentation/devicetree/bindings/usb/mediatek,mtk-xhci.txt | 1 + 1 file changed, 1 insertion(+) diff --git a/Documentation/devicetree/bindings/usb/mediatek,mtk-xhci.txt b/Documentation/devicetree/bindings/usb/mediatek,mtk-xhci.txt index 42d8814f903a..02cba4212f7d 100644 --- a/Documentation/devicetree/bindings/usb/mediatek,mtk-xhci.txt +++ b/Documentation/devicetree/bindings/usb/mediatek,mtk-xhci.txt @@ -16,6 +16,7 @@ Required properties: "mediatek,mtk-xhci" compatible string, you need SoC specific ones in addition, one of: - "mediatek,mt8173-xhci" + - "mediatek,mt8195-xhci" - reg : specifies physical base address and size of the registers - reg-names: should be "mac" for xHCI MAC and "ippc" for IP port control - interrupts : interrupt used by the controller -- 2.18.0