Some WinCE devices face connectivity issues via the NDIS interface. They fail to register, resulting in -110 timeout errors and failures during the probe procedure. In this kind of WinCE devices, the Windows-side ndis driver needs quite more time to be loaded and configured, so that the linux rndis host queries to them fail to be responded correctly on time. More specifically, when INIT is called on the WinCE side - no other requests can be served by the Client and this results in a failed QUERY afterwards. The increase of the waiting time on the side of the linux rndis host in the command-response loop leaves the INIT process to complete and respond to a QUERY, which comes afterwards. The WinCE devices with this special "feature" in their ndis driver are satisfied by this fix. Signed-off-by: Olympia Giannou <olympia.giannou@xxxxxxxxxxxxxxxxxxxx> --- drivers/net/usb/rndis_host.c | 2 +- 1 file changed, 1 insertion(+), 1 deletion(-) diff --git a/drivers/net/usb/rndis_host.c b/drivers/net/usb/rndis_host.c index bd9c07888ebb..6fa7a009a24a 100644 --- a/drivers/net/usb/rndis_host.c +++ b/drivers/net/usb/rndis_host.c @@ -201,7 +201,7 @@ int rndis_command(struct usbnet *dev, struct rndis_msg_hdr *buf, int buflen) dev_dbg(&info->control->dev, "rndis response error, code %d\n", retval); } - msleep(20); + msleep(40); } dev_dbg(&info->control->dev, "rndis response timeout\n"); return -ETIMEDOUT; -- 2.17.1