On 13.12.2019 09:31, Marek Szyprowski wrote: > PHY calibration is needed only for USB2.0 (UTMI) PHY, so skip calling > calibration code when phy_calibrate() is called for USB3.0 (PIPE3) PHY. > > Fixes: d8c80bb3b55b ("phy: exynos5-usbdrd: Calibrate LOS levels for exynos5420/5800") > Signed-off-by: Marek Szyprowski <m.szyprowski@xxxxxxxxxxx> gentle ping > --- > drivers/phy/samsung/phy-exynos5-usbdrd.c | 4 +++- > 1 file changed, 3 insertions(+), 1 deletion(-) > > diff --git a/drivers/phy/samsung/phy-exynos5-usbdrd.c b/drivers/phy/samsung/phy-exynos5-usbdrd.c > index 646259bee909..f07edd80d2f3 100644 > --- a/drivers/phy/samsung/phy-exynos5-usbdrd.c > +++ b/drivers/phy/samsung/phy-exynos5-usbdrd.c > @@ -714,7 +714,9 @@ static int exynos5_usbdrd_phy_calibrate(struct phy *phy) > struct phy_usb_instance *inst = phy_get_drvdata(phy); > struct exynos5_usbdrd_phy *phy_drd = to_usbdrd_phy(inst); > > - return exynos5420_usbdrd_phy_calibrate(phy_drd); > + if (inst->phy_cfg->id == EXYNOS5_DRDPHY_UTMI) > + return exynos5420_usbdrd_phy_calibrate(phy_drd); > + return 0; > } > > static const struct phy_ops exynos5_usbdrd_phy_ops = { Best regards -- Marek Szyprowski, PhD Samsung R&D Institute Poland