On Fri, 19 Oct 2018, Kai-Heng Feng wrote: > Devices connected under Terminus Technology Inc. Hub (1a40:0101) may > fail to work after the system resumes from suspend: > [ 206.063325] usb 3-2.4: reset full-speed USB device number 4 using xhci_hcd > [ 206.143691] usb 3-2.4: device descriptor read/64, error -32 > [ 206.351671] usb 3-2.4: device descriptor read/64, error -32 > > Info for this hub: > T: Bus=03 Lev=01 Prnt=01 Port=01 Cnt=01 Dev#= 2 Spd=480 MxCh= 4 > D: Ver= 2.00 Cls=09(hub ) Sub=00 Prot=01 MxPS=64 #Cfgs= 1 > P: Vendor=1a40 ProdID=0101 Rev=01.11 > S: Product=USB 2.0 Hub > C: #Ifs= 1 Cfg#= 1 Atr=e0 MxPwr=100mA > I: If#= 0 Alt= 0 #EPs= 1 Cls=09(hub ) Sub=00 Prot=00 Driver=hub > > Some expirements indicate that the USB devices connected to the hub are > innocent, it's the hub itself is to blame. The hub needs extra delay > time after it resets its port. > > Hence wait for extra delay, if the device is connected to this quirky > hub. > > Signed-off-by: Kai-Heng Feng <kai.heng.feng@xxxxxxxxxxxxx> > --- > v2: > - Use hub->hdev to check quirk. > - Merge the delay with TRSTRCY. Acked-by: Alan Stern <stern@xxxxxxxxxxxxxxxxxxx>