Re: [PATCH 2/7] phy: ti-pipe3: use ti_pipe3_power_off to power off the PHY during probe

[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

 



On Wed, Aug 05, 2015 at 07:42:24PM +0530, Kishon Vijay Abraham I wrote:
> Hi,
> 
> On Tuesday 04 August 2015 09:36 PM, Felipe Balbi wrote:
> > On Tue, Aug 04, 2015 at 08:50:41PM +0530, Kishon Vijay Abraham I wrote:
> >> No functional change. Previously omap_control_phy_power() was used to power
> > 
> > there is a slight functional change. You moved PHY power off from before
> > to after pm_runtime_enable(), clk_prepare_enable() and creation of the
> > PHY device. That ought to have a slight impact on how the driver
> > behaves.
> 
> okay. I'll modify the commit log. I think it won't impact the functionality as
> such since the ->init and ->power_on callbacks won't be invoked at that point.

all right, then

-- 
balbi

Attachment: signature.asc
Description: Digital signature