On Thu, 23 Jan 2014, Jonas Gorski wrote: > On Wed, 22 Jan 2014 16:17:42 -0500 (EST) > Alan Stern <stern@xxxxxxxxxxxxxxxxxxx> wrote: > > > On Wed, 22 Jan 2014, Jonas Gorski wrote: > > > > > If it's safe to set ehci->big_endian_{desc,mmio} from the _probe() > > > routine, then maybe the pdata sets in _reset() should be moved into here > > > instead of adding extra cludges/checks into _reset(). > > > > Why? What difference would it make? > > Effectivewise none, but to me it seems to be cleaner to set them once in > probe() instead of everytime reset() is called. > > I admit I don't know the code flow good enough if reset() is called > more than once in the lifetime of a hcd device. Only once. > And as I said, it would allow doing the checks the patch adds for both > DT and !DT, not just DT only. That's true. Or the checks could be moved into the probe routine. Alan Stern -- To unsubscribe from this list: send the line "unsubscribe linux-usb" in the body of a message to majordomo@xxxxxxxxxxxxxxx More majordomo info at http://vger.kernel.org/majordomo-info.html