The id of a trace option is 2 bytes short integer. When reading it from the trace file, use the tep handler associated with the file, if available, to convert the option with the correct endian order. A new helper function is introduced to read and convert 2 byte integer. Signed-off-by: Tzvetomir Stoyanov (VMware) <tz.stoyanov@xxxxxxxxx> --- lib/trace-cmd/trace-input.c | 17 ++++++++++++++--- 1 file changed, 14 insertions(+), 3 deletions(-) diff --git a/lib/trace-cmd/trace-input.c b/lib/trace-cmd/trace-input.c index ac57bc4f..0dbcdbdc 100644 --- a/lib/trace-cmd/trace-input.c +++ b/lib/trace-cmd/trace-input.c @@ -336,6 +336,18 @@ static char *read_string(struct tracecmd_input *handle) return NULL; } +static int read2(struct tracecmd_input *handle, unsigned short *size) +{ + struct tep_handle *pevent = handle->pevent; + unsigned short data; + + if (do_read_check(handle, &data, 2)) + return -1; + + *size = tep_read_number(pevent, &data, 2); + return 0; +} + static int read4(struct tracecmd_input *handle, unsigned int *size) { struct tep_handle *pevent = handle->pevent; @@ -2660,16 +2672,15 @@ static int handle_options(struct tracecmd_input *handle) handle->options_start = lseek64(handle->fd, 0, SEEK_CUR); for (;;) { - if (do_read_check(handle, &option, 2)) + if (read2(handle, &option)) return -1; if (option == TRACECMD_OPTION_DONE) break; /* next 4 bytes is the size of the option */ - if (do_read_check(handle, &size, 4)) + if (read4(handle, &size)) return -1; - size = tep_read_number(handle->pevent, &size, 4); buf = malloc(size); if (!buf) return -ENOMEM; -- 2.31.1