Some NVIDIA PMUs like the NVLINK-C2C, CNVLINK, and PCIE PMU provide port filtering. If the port filter is set to zero, the counter of these PMUs will not capture any event. To avoid meaningless experiment, the driver sets the port filter value to a default non-zero value. Signed-off-by: Besar Wicaksono <bwicaksono@xxxxxxxxxx> --- Documentation/admin-guide/perf/nvidia-pmu.rst | 12 ++++++++---- drivers/perf/arm_cspmu/nvidia_cspmu.c | 6 ++++-- 2 files changed, 12 insertions(+), 6 deletions(-) diff --git a/Documentation/admin-guide/perf/nvidia-pmu.rst b/Documentation/admin-guide/perf/nvidia-pmu.rst index 4cfc806070d7..f538ef67e0e8 100644 --- a/Documentation/admin-guide/perf/nvidia-pmu.rst +++ b/Documentation/admin-guide/perf/nvidia-pmu.rst @@ -89,7 +89,8 @@ Example usage: The NVLink-C2C has two ports that can be connected to one GPU (occupying both ports) or to two GPUs (one GPU per port). The user can use "port" bitmap parameter to select the port(s) to monitor. Each bit represents the port number, -e.g. "port=0x1" corresponds to port 0 and "port=0x3" is for port 0 and 1. +e.g. "port=0x1" corresponds to port 0 and "port=0x3" is for port 0 and 1. The +PMU will monitor both ports by default if not specified. Example for port filtering: @@ -134,7 +135,8 @@ Example usage: The NVLink-C2C has two ports that can be connected to one GPU (occupying both ports) or to two GPUs (one GPU per port). The user can use "port" bitmap parameter to select the port(s) to monitor. Each bit represents the port number, -e.g. "port=0x1" corresponds to port 0 and "port=0x3" is for port 0 and 1. +e.g. "port=0x1" corresponds to port 0 and "port=0x3" is for port 0 and 1. The +PMU will monitor both ports by default if not specified. Example for port filtering: @@ -160,7 +162,8 @@ see /sys/bus/event_source/devices/nvidia_cnvlink_pmu_<socket-id>. Each SoC socket can be connected to one or more sockets via CNVLink. The user can use "rem_socket" bitmap parameter to select the remote socket(s) to monitor. Each bit represents the socket number, e.g. "rem_socket=0xE" corresponds to -socket 1 to 3. +socket 1 to 3. The PMU will monitor all remote sockets by default if not +specified. /sys/bus/event_source/devices/nvidia_cnvlink_pmu_<socket-id>/format/rem_socket shows the valid bits that can be set in the "rem_socket" parameter. @@ -199,7 +202,8 @@ see /sys/bus/event_source/devices/nvidia_pcie_pmu_<socket-id>. Each SoC socket can support multiple root ports. The user can use "root_port" bitmap parameter to select the port(s) to monitor, i.e. -"root_port=0xF" corresponds to root port 0 to 3. +"root_port=0xF" corresponds to root port 0 to 3. The PMU will monitor all root +ports by default if not specified. /sys/bus/event_source/devices/nvidia_pcie_pmu_<socket-id>/format/root_port shows the valid bits that can be set in the "root_port" parameter. diff --git a/drivers/perf/arm_cspmu/nvidia_cspmu.c b/drivers/perf/arm_cspmu/nvidia_cspmu.c index 7ab7d76e4ca1..b926861b133a 100644 --- a/drivers/perf/arm_cspmu/nvidia_cspmu.c +++ b/drivers/perf/arm_cspmu/nvidia_cspmu.c @@ -175,10 +175,12 @@ static u32 nv_cspmu_event_filter(const struct perf_event *event) const struct nv_cspmu_ctx *ctx = to_nv_cspmu_ctx(to_arm_cspmu(event->pmu)); - if (ctx->filter_mask == 0) + const u32 filter_val = event->attr.config1 & ctx->filter_mask; + + if (filter_val == 0) return ctx->filter_default_val; - return event->attr.config1 & ctx->filter_mask; + return filter_val; } enum nv_cspmu_name_fmt { -- 2.34.1