22.05.2020 15:26, Thierry Reding пишет: > On Wed, May 20, 2020 at 01:08:57PM -0700, Sowjanya Komatineni wrote: >> When auto calibration timeouts, calibration is disabled and fail-safe >> drive strength values are programmed based on the signal voltage. >> >> Different fail-safe drive strength values based on voltage are >> applicable only for SoCs supporting 3V3 and 1V8 pad controls. >> >> So, this patch avoids reading these properties from the device tree >> for SoCs not using pad controls and the warning of missing properties >> will not show up on these SoC platforms. >> >> Signed-off-by: Sowjanya Komatineni <skomatineni@xxxxxxxxxx> >> --- >> drivers/mmc/host/sdhci-tegra.c | 57 ++++++++++++++++++++++++------------------ >> 1 file changed, 33 insertions(+), 24 deletions(-) >> >> diff --git a/drivers/mmc/host/sdhci-tegra.c b/drivers/mmc/host/sdhci-tegra.c >> index 3e2c510..141b49b 100644 >> --- a/drivers/mmc/host/sdhci-tegra.c >> +++ b/drivers/mmc/host/sdhci-tegra.c >> @@ -605,6 +605,39 @@ static void tegra_sdhci_parse_pad_autocal_dt(struct sdhci_host *host) >> autocal->pull_down_1v8 = 0; >> >> err = device_property_read_u32(host->mmc->parent, >> + "nvidia,pad-autocal-pull-up-offset-sdr104", >> + &autocal->pull_up_sdr104); >> + if (err) >> + autocal->pull_up_sdr104 = autocal->pull_up_1v8; >> + >> + err = device_property_read_u32(host->mmc->parent, >> + "nvidia,pad-autocal-pull-down-offset-sdr104", >> + &autocal->pull_down_sdr104); >> + if (err) >> + autocal->pull_down_sdr104 = autocal->pull_down_1v8; >> + >> + err = device_property_read_u32(host->mmc->parent, >> + "nvidia,pad-autocal-pull-up-offset-hs400", >> + &autocal->pull_up_hs400); >> + if (err) >> + autocal->pull_up_hs400 = autocal->pull_up_1v8; >> + >> + err = device_property_read_u32(host->mmc->parent, >> + "nvidia,pad-autocal-pull-down-offset-hs400", >> + &autocal->pull_down_hs400); >> + if (err) >> + autocal->pull_down_hs400 = autocal->pull_down_1v8; >> + >> + /* >> + * Different fail-safe drive strength values based on the signaling >> + * voltage are applicable for SoCs supporting 3V3 and 1V8 pad controls. >> + * So, avoid reading below device tree properies for SoCs that don't >> + * have NVQUIRK_NEEDS_PAD_CONTROL. >> + */ >> + if (!(tegra_host->soc_data->nvquirks & NVQUIRK_NEEDS_PAD_CONTROL)) >> + return; > > Hm... so what exactly is the difference between NVQUIRK_HAS_PADCALIB? I > think Tegra30 will also end up calling tegra_sdhci_set_padctrl(), but it > will then write the default (0) value for these drive strength. Is that > okay? It won't write 0, but skip the writing if values are 0. Technically T30+ supports the customized strengths, but I'm not sure whether it was ever tested and whether it's really needed. I think Sowjanya said before that the default values are always okay for older SoCs.