25.03.2020 04:15, Sowjanya Komatineni пишет: > > On 3/24/20 6:08 PM, Sowjanya Komatineni wrote: >> >> On 3/24/20 5:34 PM, Dmitry Osipenko wrote: >>> External email: Use caution opening links or attachments >>> >>> >>> 23.03.2020 20:52, Sowjanya Komatineni пишет: >>>> +static void tegra_channel_vi_soft_reset(struct tegra_vi_channel *chan) >>>> +{ >>>> + /* disable clock gating to enable continuous clock */ >>>> + tegra_vi_write(chan, TEGRA_VI_CFG_CG_CTRL, 0); >>>> + /* >>>> + * Soft reset memory client interface, pixel format logic, sensor >>>> + * control logic, and a shadow copy logic to bring VI to clean >>>> state. >>>> + */ >>>> + vi_csi_write(chan, TEGRA_VI_CSI_SW_RESET, 0xf); >>>> + usleep_range(100, 200); >>>> + vi_csi_write(chan, TEGRA_VI_CSI_SW_RESET, 0x0); >>> Is it safe to reset MCCIF without blocking and flushing memory requests >>> at first? >> Yes to bring VI to clean state on errors its recommended by HW design >> team. > BTW, just to be clear this is Software reset. Ok