06.12.2019 05:48, Sowjanya Komatineni пишет: > Current Tegra clock driver registers PMC clocks clk_out_1, clk_out_2, > clk_out_3 and blink output in tegra_pmc_init() which does direct Tegra > PMC access during clk_ops and these PMC register read and write access > will not happen when PMC is in secure mode. > > Any direct PMC register access from non-secure world will not go > through and all the PMC clocks and blink control are done in Tegra PMC > driver with PMC as clock provider. > > This patch removes tegra_pmc_clk_init along with corresponding clk ids > from Tegra clock driver. > > Signed-off-by: Sowjanya Komatineni <skomatineni@xxxxxxxxxx> > --- [snip] > @@ -1230,9 +1222,6 @@ static struct tegra_clk_init_table init_table[] __initdata = { > { TEGRA30_CLK_PLL_A, TEGRA30_CLK_CLK_MAX, 564480000, 1 }, > { TEGRA30_CLK_PLL_A_OUT0, TEGRA30_CLK_CLK_MAX, 11289600, 1 }, > { TEGRA30_CLK_EXTERN1, TEGRA30_CLK_PLL_A_OUT0, 0, 1 }, Perhaps these clocks do not need to be always-enabled? [snip]