>The number of global interrupts has never been related to the number of context interrupts :/

Yeah,  They are not related. I was trying to use minimum irq entries in the DT node as they both would achieve the same functionality.

>Clearly you have one combined interrupt output per SMMU - describing those as one global interrupt and the first two context bank interrupts respectively makes far less sense than calling them 3 global interrupts, not least because the latter is strictly true.

Will update to 3 in next patch to make it better for readability.

-KR