On Tue, Feb 26, 2019 at 04:07:55PM +0000, Jon Hunter wrote: > The VCC supply property is not populated for the temperature sensor on > the P2888 board and so the following warning is observed on boot ... > > lm90 0-004c: 0-004c supply vcc not found, using dummy regulator > > On the P2888 board, the VCC supply for the temperature sensor is > connected to the 'vdd_1v8ls' rail. Add the 'vcc-supply' property for > the temperature sensor to prevent this warning message from occurring. > > Fixes: 8b457812f54b ('arm64: tegra: Add temperature sensor on P2888') > > Signed-off-by: Jon Hunter <jonathanh@xxxxxxxxxx> > --- > arch/arm64/boot/dts/nvidia/tegra194-p2888.dtsi | 1 + > 1 file changed, 1 insertion(+) Applied to for-5.2/arm64/dt, thanks. Thierry