On Fri, Sep 21, 2018 at 06:01:49PM -0400, ryang wrote: > The current behavior is that clk_round_rate would return the same clock > rate passed to it for valid PLL configurations. This change will return > the exact rate the PLL will provide in accordance with clk API. > > Signed-off-by: ryang <decatf@xxxxxxxxx> > --- > drivers/clk/tegra/clk-pll.c | 7 ++++++- > 1 file changed, 6 insertions(+), 1 deletion(-) > > diff --git a/drivers/clk/tegra/clk-pll.c b/drivers/clk/tegra/clk-pll.c > index 17a058c3bbc1..36014a6ec42e 100644 > --- a/drivers/clk/tegra/clk-pll.c > +++ b/drivers/clk/tegra/clk-pll.c > @@ -595,7 +595,12 @@ static int _calc_rate(struct clk_hw *hw, struct tegra_clk_pll_freq_table *cfg, > return -EINVAL; > } > > - cfg->output_rate >>= p_div; > + if (cfg->m == 0) { > + cfg->output_rate = 0; I think a WARN_ON() is appropriate here. the input divider should never be 0. Peter. > + } else { > + cfg->output_rate = cfg->n * DIV_ROUND_UP(parent_rate, cfg->m); > + cfg->output_rate >>= p_div; > + } > > if (pll->params->pdiv_tohw) { > ret = _p_div_to_hw(hw, 1 << p_div); > -- > 2.17.1 >