On 02/07/15 10:03, Uwe Kleine-König wrote: > Hello Boris, > > On Wed, Jul 01, 2015 at 10:21:46AM +0200, Boris Brezillon wrote: >> This series adds support for atomic PWM update, or ITO, the capability >> to update all the parameters of a PWM device (enabled/disabled, period, >> duty and polarity) in one go. > on first reading the subject of your series I thought it was about > asserting that the newly set config is active before the call to > pwm_config (et al) returns. That's a problem I addressed a few times in > the past. I wonder if it's only me or if a different wording should be > used for "update all parameters with a single function call". In my vocabulary "blocking" means that the work is done before the function returns, and "atomic" means the work is done in one step. Tomi