From: Thierry Reding <treding@xxxxxxxxxx> The number of resets controls is 32 times the number of peripheral register banks rather than 32 times the number of clocks. This reduces (drastically) the number of reset controls registered from 10080 (315 clocks * 32) to 224 (6 peripheral register banks * 32). This also fixes a potential crash because trying to use any of the excess reset controls (224-10079) would have caused accesses beyond the array bounds of the peripheral register banks definition array. Cc: Peter De Schrijver <pdeschrijver@xxxxxxxxxx> Cc: Prashant Gaikwad <pgaikwad@xxxxxxxxxx> Fixes: 6d5b988e7dc5 ("clk: tegra: implement a reset driver") Cc: stable@xxxxxxxxxxxxxxx # 3.14+ Signed-off-by: Thierry Reding <treding@xxxxxxxxxx> --- drivers/clk/tegra/clk.c | 2 +- 1 file changed, 1 insertion(+), 1 deletion(-) diff --git a/drivers/clk/tegra/clk.c b/drivers/clk/tegra/clk.c index 8b9b7a27616b..41cd87c67be6 100644 --- a/drivers/clk/tegra/clk.c +++ b/drivers/clk/tegra/clk.c @@ -286,7 +286,7 @@ void __init tegra_add_of_provider(struct device_node *np) of_clk_add_provider(np, of_clk_src_onecell_get, &clk_data); rst_ctlr.of_node = np; - rst_ctlr.nr_resets = clk_num * 32; + rst_ctlr.nr_resets = periph_banks * 32; reset_controller_register(&rst_ctlr); } -- 2.3.2 -- To unsubscribe from this list: send the line "unsubscribe linux-tegra" in the body of a message to majordomo@xxxxxxxxxxxxxxx More majordomo info at http://vger.kernel.org/majordomo-info.html