Re: [PATCH v3 3/4] thermal: add more description for thermal-zones

[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

 



On 08/25/2014 07:07 PM, Eduardo Valentin wrote:
> Hello Wei Ni,
> 
> On Mon, Aug 25, 2014 at 02:29:47PM +0800, Wei Ni wrote:
>> Add more description for the "polling-delay" property.
>> Set "trips" and "cooling maps" as optional property, because
>> if missing these two sub-nodes, the thermal zone device still
>> work properly.
>>
>> Signed-off-by: Wei Ni <wni@xxxxxxxxxx>
>> ---
>>  Documentation/devicetree/bindings/thermal/thermal.txt | 10 ++++++----
>>  1 file changed, 6 insertions(+), 4 deletions(-)
>>
>> diff --git a/Documentation/devicetree/bindings/thermal/thermal.txt b/Documentation/devicetree/bindings/thermal/thermal.txt
>> index f5db6b7..e3d3ed9 100644
>> --- a/Documentation/devicetree/bindings/thermal/thermal.txt
>> +++ b/Documentation/devicetree/bindings/thermal/thermal.txt
>> @@ -136,8 +136,8 @@ containing trip nodes and one sub-node containing all the zone cooling maps.
>>  
>>  Required properties:
>>  - polling-delay:	The maximum number of milliseconds to wait between polls
>> -  Type: unsigned	when checking this thermal zone.
>> -  Size: one cell
>> +  Type: unsigned	when checking this thermal zone. If this value is 0, the
>> +  Size: one cell	driver will not run polling queue, but just cancel it.
>>  
> 
> The description above is specific to Linux kernel implementation
> nomenclature. DT description needs to be OS agnostic.

Normally, the user may think a delay of 0 means that software
continually polls this zone, but in here it mean no polling. May be it's
better to add this description.

> 
>>  - polling-delay-passive: The maximum number of milliseconds to wait
>>    Type: unsigned	between polls when performing passive cooling.
>> @@ -148,14 +148,16 @@ Required properties:
>>    phandles + sensor
>>    specifier
>>  
>> +Optional property:
>>  - trips:		A sub-node which is a container of only trip point nodes
>>    Type: sub-node	required to describe the thermal zone.
>>  
>>  - cooling-maps:		A sub-node which is a container of only cooling device
>>    Type: sub-node	map nodes, used to describe the relation between trips
>> -			and cooling devices.
>> +			and cooling devices. If missing the "trips" property,
>> +			This sub-node will not be parsed, because no trips can
>> +			be bound to cooling devices.
> 
> Do you mean if the thermal zone misses the "trips" property? Actually,
> the binding describes both, cooling-maps and trips, as required
> properties. Thus, both needs to be in place to consider the thermal zone
> as a proper described zone.
> 
>>  
>> -Optional property:
>>  - coefficients:		An array of integers (one signed cell) containing
>>    Type: array		coefficients to compose a linear relation between
>>    Elem size: one cell	the sensors listed in the thermal-sensors property.
>> -- 
>> 1.8.1.5
>>

--
To unsubscribe from this list: send the line "unsubscribe linux-tegra" in
the body of a message to majordomo@xxxxxxxxxxxxxxx
More majordomo info at  http://vger.kernel.org/majordomo-info.html