Jamuel P. Starkey schrieb:
Does this release fix the segfault issue you guys have been working on the last few weeks related to low bandwidth links between target and initiator?
It does.
Although with default open-iscsi settings, your initiator will report
I/O errors very soon.
It is because iscsid normally waits only 15 seconds for a Nop-out
response, which is surely not enough for slow links (and perhaps some
DRBD or similar setups).
You can increase this value with (i.e. to 1200 seconds) per target:
# iscsiadm -m node -T iqn.2009-02.com.example:some.target -o update -n
node.session.err_timeo.abort_timeout -v 1200
Or globally, in iscsid.conf:
node.session.err_timeo.abort_timeout = 1200
Other initiators (not open-iscsi) perhaps will need similar settings.
--
Tomasz Chmielewski
http://wpkg.org
--
To unsubscribe from this list: send the line "unsubscribe stgt" in
the body of a message to majordomo@xxxxxxxxxxxxxxx
More majordomo info at http://vger.kernel.org/majordomo-info.html