On Wed, May 24, 2023 at 11:19:45AM +0200, Boerge Struempfel wrote: > By default, the spi-imx controller pulls the mosi line high, whenever it > is idle. This behaviour can be inverted per CS by setting the > corresponding DATA_CTL bit in the config register of the controller. This doesn't apply against current code, please check and resend.