On Fri, Nov 18, 2022 at 11:36:27AM +0100, Carlo Caione wrote: > On 17/11/2022 15:59, Mark Brown wrote: > > So this is an issue in the MIPI DBI code where the interpretation of the > > buffer passed in depends on both the a caller parameter and the > > capabilities of the underlying SPI controller, meaning that a driver can > > suddenly become buggy when used with a new controller? > The MIPI DBI code is fine, in fact it is doing the correct thing in the > mipi_dbi_typec3_command() function. The problem is that the ILI9486 > driver is hijacking that function installing its own hook that is wrong. Ah, I see - it's causing confusion because it peers into the internals of the underlying code. > The problem arrives when your controller does support 16-bits, so your > data is not swapped, but you still put the data on the bus with 8-bit > transfers. Why would you need to use 8 bit transfers if the controller supports 16 bits?