On Tue, 15 Nov 2022 19:10:00 +0100, Frieder Schrempf wrote: > From: Frieder Schrempf <frieder.schrempf@xxxxxxxxxx> > > In case the requested bus clock is higher than the input clock, the correct > dividers (pre = 0, post = 0) are returned from mx51_ecspi_clkdiv(), but > *fres is left uninitialized and therefore contains an arbitrary value. > > This causes trouble for the recently introduced PIO polling feature as the > value in spi_imx->spi_bus_clk is used there to calculate for which > transfers to enable PIO polling. > > [...] Applied to broonie/spi.git for-next Thanks! [1/1] spi: spi-imx: Fix spi_bus_clk if requested clock is higher than input clock commit: db2d2dc9a0b58c6faefb6b002fdbed4f0362d1a4 All being well this means that it will be integrated into the linux-next tree (usually sometime in the next 24 hours) and sent to Linus during the next merge window (or sooner if it is a bug fix), however if problems are discovered then the patch may be dropped or reverted. You may get further e-mails resulting from automated or manual testing and review of the tree, please engage with people reporting problems and send followup patches addressing any issues that are reported if needed. If any updates are required or you are submitting further changes they should be sent as incremental updates against current git, existing patches will not be replaced. Please add any relevant lists and maintainers to the CCs when replying to this mail. Thanks, Mark