If there are 2 slaves or more on a spi bus, e.g. A and B, we processed a transfer to A, the CS will be selected for A whose 'last_cs_enable' will be recorded to true at the same time. Then we processed a transfer to B, the CS will be switched to B. And then if we transmit data to A again, it will not enable CS back to A because 'last_cs_enable' is true. In addition, if CS is not disabled, Some controllers in automatic transmission state will receive unpredictable data, such as Cadence SPI controller. Signed-off-by: Yun Zhou <yun.zhou@xxxxxxxxxxxxx> --- drivers/spi/spi.c | 8 ++------ 1 file changed, 2 insertions(+), 6 deletions(-) diff --git a/drivers/spi/spi.c b/drivers/spi/spi.c index fdd530b150a7..ebbba0b08186 100644 --- a/drivers/spi/spi.c +++ b/drivers/spi/spi.c @@ -1417,7 +1417,6 @@ static int spi_transfer_one_message(struct spi_controller *ctlr, struct spi_message *msg) { struct spi_transfer *xfer; - bool keep_cs = false; int ret = 0; struct spi_statistics *statm = &ctlr->statistics; struct spi_statistics *stats = &msg->spi->statistics; @@ -1486,10 +1485,8 @@ static int spi_transfer_one_message(struct spi_controller *ctlr, spi_transfer_delay_exec(xfer); if (xfer->cs_change) { - if (list_is_last(&xfer->transfer_list, + if (!list_is_last(&xfer->transfer_list, &msg->transfers)) { - keep_cs = true; - } else { spi_set_cs(msg->spi, false, false); _spi_transfer_cs_change_delay(msg, xfer); spi_set_cs(msg->spi, true, false); @@ -1500,8 +1497,7 @@ static int spi_transfer_one_message(struct spi_controller *ctlr, } out: - if (ret != 0 || !keep_cs) - spi_set_cs(msg->spi, false, false); + spi_set_cs(msg->spi, false, false); if (msg->status == -EINPROGRESS) msg->status = ret; -- 2.26.1