pm_runtime_get_sync() increments the runtime PM usage counter even when it returns an error code. Thus a pairing decrement is needed on the error handling path to keep the counter balanced. Signed-off-by: Dinghao Liu <dinghao.liu@xxxxxxxxxx> --- Changelog: v2: - Use pm_runtime_put_noidle() instead of pm_runtime_put(). --- drivers/spi/spi-tegra20-slink.c | 1 + 1 file changed, 1 insertion(+) diff --git a/drivers/spi/spi-tegra20-slink.c b/drivers/spi/spi-tegra20-slink.c index 7f4d932dade7..a07b72e9c344 100644 --- a/drivers/spi/spi-tegra20-slink.c +++ b/drivers/spi/spi-tegra20-slink.c @@ -1118,6 +1118,7 @@ static int tegra_slink_probe(struct platform_device *pdev) ret = pm_runtime_get_sync(&pdev->dev); if (ret < 0) { dev_err(&pdev->dev, "pm runtime get failed, e = %d\n", ret); + pm_runtime_put_noidle(&pdev->dev); goto exit_pm_disable; } tspi->def_command_reg = SLINK_M_S; -- 2.17.1