On Mon, Apr 17, 2017 at 09:29:38PM +0200, Hauke Mehrtens wrote: > From: Martin Blumenstingl <martin.blumenstingl@xxxxxxxxxxxxxx> > > Compared to the old xrx200_phy_fw driver the new version has multiple > enhancements. The name of the firmware files does not have to be added > to all .dts files anymore - one now configures the GPHY mode (FE or GE) > instead. Each GPHY can now also boot separate firmware (thus mixing of > GE and FE GPHYs is now possible). > The new implementation is based on the RCU syscon-mfd and uses the > reeset_controller framework instead of raw RCU register reads/writes. > > Signed-off-by: Hauke Mehrtens <hauke@xxxxxxxxxx> > --- > .../devicetree/bindings/mips/lantiq/rcu-gphy.txt | 54 +++++ > arch/mips/lantiq/xway/sysctrl.c | 4 +- > drivers/soc/lantiq/Makefile | 1 + > drivers/soc/lantiq/gphy.c | 242 +++++++++++++++++++++ > include/dt-bindings/mips/lantiq_rcu_gphy.h | 15 ++ > 5 files changed, 314 insertions(+), 2 deletions(-) > create mode 100644 Documentation/devicetree/bindings/mips/lantiq/rcu-gphy.txt > create mode 100644 drivers/soc/lantiq/gphy.c > create mode 100644 include/dt-bindings/mips/lantiq_rcu_gphy.h > > diff --git a/Documentation/devicetree/bindings/mips/lantiq/rcu-gphy.txt b/Documentation/devicetree/bindings/mips/lantiq/rcu-gphy.txt > new file mode 100644 > index 000000000000..d525c7ce9f0b > --- /dev/null > +++ b/Documentation/devicetree/bindings/mips/lantiq/rcu-gphy.txt > @@ -0,0 +1,54 @@ > +Lantiq XWAY SoC GPHY binding > +============================ > + > +This binding describes a software-defined ethernet PHY, provided by the RCU > +module on newer Lantiq XWAY SoCs (xRX200 and newer). > +This depends on binary firmware blobs which must be provided by userspace. Where the blobs come from is not relevant. > + > + > +------------------------------------------------------------------------------- > +Required properties (controller (parent) node): > +- compatible : Should be one of > + "lantiq,xrx200a1x-rcu-gphy" > + "lantiq,xrx200a2x-rcu-gphy" > + "lantiq,xrx300-rcu-gphy" > + "lantiq,xrx330-rcu-gphy" > +- lantiq,rcu-syscon : A phandle and offset to the GPHY address registers in > + the RCU > +- resets : Must reference the RCU GPHY reset bit > +- reset-names : One entry, value must be "gphy" or optional "gphy2" > + > +Optional properties (port (child) node): > +- lantiq,gphy-mode : GPHY_MODE_GE (default) or GPHY_MODE_FE as defined in > + <dt-bindings/mips/lantiq_xway_gphy.h> > +- clocks : A reference to the (PMU) GPHY clock gate > +- clock-names : If clocks is given then this must be "gphy" Kind of pointless to have a name for a single clock. > + > + > +------------------------------------------------------------------------------- > +Example for the GPHys on the xRX200 SoCs: > + > +#include <dt-bindings/mips/lantiq_rcu_gphy.h> > + gphy0: rcu_gphy@0 { Use generic node names: phy@... > + compatible = "lantiq,xrx200a2x-rcu-gphy"; > + reg = <0>; > + > + lantiq,rcu-syscon = <&rcu0 0x20>; Could the phy just be a child of the rcu? Then you don't need a phandle here and 0x20 becomes the reg address. > + resets = <&rcu_reset0 31>, <&rcu_reset1 7>; > + reset-names = "gphy", "gphy2"; > + lantiq,gphy-mode = <GPHY_MODE_GE>; > + clocks = <&pmu0 XRX200_PMU_GATE_GPHY>; > + clock-names = "gphy"; > + }; > + > + gphy1: rcu_gphy@1 { > + compatible = "lantiq,xrx200a2x-rcu-gphy"; > + reg = <0>; > + > + lantiq,rcu-syscon = <&rcu0 0x68>; > + resets = <&rcu_reset0 29>, <&rcu_reset1 6>; > + reset-names = "gphy", "gphy2"; > + lantiq,gphy-mode = <GPHY_MODE_FE>; > + clocks = <&pmu0 XRX200_PMU_GATE_GPHY>; > + clock-names = "gphy"; > + }; -- To unsubscribe from this list: send the line "unsubscribe linux-spi" in the body of a message to majordomo@xxxxxxxxxxxxxxx More majordomo info at http://vger.kernel.org/majordomo-info.html