Re: [PATCH 2/2] spi: Add DT bindings documentation for Netlogic XLP SPI controller

[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

 



On Wed, Aug 19, 2015 at 10:39:17AM +0530, kamlakant.patel@xxxxxxxxxxxx wrote:

> +- clock-frequency : [OPTIONAL] Input clock frequency to the SPI block in Hz.
> +		    Default is 133333333 Hz.

I would expect this to be specifying the input clock to the block via
the standard clock binding rather than just hard coding a number in
here.  This means the binding will continue to work for more complex
sysetems with programmable clocks and is generally more standard.  SoCs
can still specify hard coded fixed frequency clocks as fixed clocks in
the DT.

Attachment: signature.asc
Description: Digital signature


[Index of Archives]     [Linux Kernel]     [Linux ARM (vger)]     [Linux ARM MSM]     [Linux Omap]     [Linux Arm]     [Linux Tegra]     [Fedora ARM]     [Linux for Samsung SOC]     [eCos]     [Linux Fastboot]     [Gcc Help]     [Git]     [DCCP]     [IETF Announce]     [Security]     [Linux MIPS]     [Yosemite Campsites]