Hi Jarkko, On 9/4/2022 7:04 PM, Jarkko Sakkinen wrote: > The final enclave address range (referred as ELRANGE in Intel SDM) > calculation is a reminiscent of signing tool being a separate command-line > utility, and sigstruct being produced during the compilation. Given that > nowadays the sigstruct is calculated on-fly, use the readily calculated > encl->encl_size instead, in order to remove duplicate code. > > Signed-off-by: Jarkko Sakkinen <jarkko@xxxxxxxxxx> Thank you very much. Reviewed-by: Reinette Chatre <reinette.chatre@xxxxxxxxx> Reinette