On 07/16/2014 06:06 PM, Felipe Balbi wrote: >>> well, other than in probe and other functions which need to >>> make sure clocks are on, but it seems unnecessary to >>> enable/disable in every function. >> >> What do you have in mind? Do you plan to let the uart on while >> the minicom is attached but is doing nothing? In that case, >> ->startup() and ->shutdown() should be enough. > > no the idea was to keep it on for as long as it's transferring > characters and idle it otherwise, if that can't be done easily, > then I guess your way is the only way. But maybe we have to add some additional logic here to keep it up for the transfer. I've been just (maybe over)thinking: If you send 300 bytes over DMA via 300 baud it should take 10 seconds. The PM-timeout could hit before the transfer is complete. Same thing with hw-flowcontrol where you could get stalled for a few seconds. However it doesn't seem to be a problem in current omap-serial driver. > cheers Sebastian -- To unsubscribe from this list: send the line "unsubscribe linux-serial" in the body of a message to majordomo@xxxxxxxxxxxxxxx More majordomo info at http://vger.kernel.org/majordomo-info.html