On 04/09/2015 09:00 PM, Himanshu Madhani wrote: > From: Sawan Chandak <sawan.chandak@xxxxxxxxxx> > > On some vendor switches, when switch port is toggled (down /up), > then in some condition driver tries to configure virtual port, > before FW is actually in ready state to process any commands on wire. > At this time, configuring virtual port can fail. Add fix in driver > to make driver wait, for FW to be ready state before > > Signed-off-by: Sawan Chandak <sawan.chandak@xxxxxxxxxx> > Signed-off-by: Himanshu Madhani <himanshu.madhani@xxxxxxxxxx> > --- Reviewed-by: Hannes Reinecke <hare@xxxxxxx> Cheers, Hannes -- Dr. Hannes Reinecke zSeries & Storage hare@xxxxxxx +49 911 74053 688 SUSE LINUX Products GmbH, Maxfeldstr. 5, 90409 Nürnberg GF: J. Hawn, J. Guild, F. Imendörffer, HRB 16746 (AG Nürnberg) -- To unsubscribe from this list: send the line "unsubscribe linux-scsi" in the body of a message to majordomo@xxxxxxxxxxxxxxx More majordomo info at http://vger.kernel.org/majordomo-info.html