On Mon, 30 Apr 2012, Norman Diamond wrote: > I wish I could get a broken Prolific bridge to test together with > mine. I just realized -- I have a buggy Prolific bridge here. It's not the same model as yours; the vendor ID is 0x067b but the product ID is 0x3507. With the disk it is currently connected to, it does indeed report a capacity that is too large by 1, and the correct value is a multiple of 63. Alan Stern -- To unsubscribe from this list: send the line "unsubscribe linux-scsi" in the body of a message to majordomo@xxxxxxxxxxxxxxx More majordomo info at http://vger.kernel.org/majordomo-info.html