mpt2sas: bug in disk ordering?

[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

 



Hi all,

I'm having a minor issue with the disk ordering using an LSI 9211-8i
(mpt2sas) controller.

If i go into the controllers SAS config utility during boot I can
identify the disks in the slots.

disk 0 -> slot 0, disk 1 -> slot 1, etc.. everyhting is fine.

When I boot into debian linux lenny (using the latest backports
2.6.32-31 kernel, this kernel has version 02.100.03.00 of the mpt2sas
driver)

The disks are ordered this way:

/dev/sda = internal SSD connected to the MB

/dev/sdb = slot 0
/dev/sdc = slot 1
/dev/sdd = slot 2
/dev/sde = slot 3
/dev/sdf = slot 7 (!)
/dev/sdg = slot 4
/dev/sdh = slot 5
/dev/sdi = slot 6

So it seems the first 4 disks connected to SAS port 1 are ordered
correctly and the last 4 disks are not.

When I check /dev/disk/by-path i see the following:

lrwxrwxrwx 1 root root   9 2011-05-13 10:52 pci-0000:04:00.0-sas-
0x500605b001d161b0:1:0-0x4433221103000000:0 -> ../../sdb
lrwxrwxrwx 1 root root   9 2011-05-13 10:52
pci-0000:04:00.0-sas-0x500605b001d161b0:1:1-0x4433221102000000:0 ->
../../sdc
lrwxrwxrwx 1 root root   9 2011-05-13 10:52
pci-0000:04:00.0-sas-0x500605b001d161b0:1:2-0x4433221101000000:0 ->
../../sdd
lrwxrwxrwx 1 root root   9 2011-05-13 10:52
pci-0000:04:00.0-sas-0x500605b001d161b0:1:3-0x4433221100000000:0 ->
../../sde
lrwxrwxrwx 1 root root   9 2011-05-13 10:52
pci-0000:04:00.0-sas-0x500605b001d161b0:1:4-0x4433221104000000:0 ->
../../sdf
lrwxrwxrwx 1 root root   9 2011-05-13 10:52
pci-0000:04:00.0-sas-0x500605b001d161b0:1:5-0x4433221107000000:0 ->
../../sdg
lrwxrwxrwx 1 root root   9 2011-05-13 10:52
pci-0000:04:00.0-sas-0x500605b001d161b0:1:6-0x4433221106000000:0 ->
../../sdh
lrwxrwxrwx 1 root root   9 2011-05-13 10:52
pci-0000:04:00.0-sas-0x500605b001d161b0:1:7-0x4433221105000000:0 ->
../../sdi

This LOOKS as it should but right now it is not really correct because
1:7 indicates that it should be physical slot 7 (sdi is in slot 6 and
not in slot 7)

When i use the sas2ircu command line util to LOCATE the disks and I
use 1:7 to locate, slot 7 lights up (NOT disk sdi)

Is this behavior fixed in a newer version of the driver, and if so
what is the corresponding patch to fix this?

Kind regards,

Caspar Smit
--
To unsubscribe from this list: send the line "unsubscribe linux-scsi" in
the body of a message to majordomo@xxxxxxxxxxxxxxx
More majordomo info at  http://vger.kernel.org/majordomo-info.html


[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]
[Index of Archives]     [SCSI Target Devel]     [Linux SCSI Target Infrastructure]     [Kernel Newbies]     [IDE]     [Security]     [Git]     [Netfilter]     [Bugtraq]     [Yosemite News]     [MIPS Linux]     [ARM Linux]     [Linux Security]     [Linux RAID]     [Linux ATA RAID]     [Linux IIO]     [Samba]     [Device Mapper]
  Powered by Linux