[PATCH 3/9] mpt2sas: Raid 10 Value is showing as Raid 1E in /va/log/messages

[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

 



When a volume is activated, the driver will recieve a pair of ir config change
events to remove the foreign volume, then add the native.
In the process of the removal event, the hidden raid componet is removed from
the parent.When the disks is added back, the adding of the port fails becuase
there is no instance of the device in its parent.
To fix this issue, the driver needs to call mpt2sas_transport_update_links()
prior to calling _scsih_add_device. In addition, we added sanity checks on
volume add and removal to ignore events for foreign volumes.

---

Signed-off-by: Kashyap Desai <kashyap.desai@xxxxxxx>
Signed-off-by: Eric Moore <Eric.moore@xxxxxxx>
---
diff --git a/drivers/scsi/mpt2sas/mpt2sas_scsih.c b/drivers/scsi/mpt2sas/mpt2sas_scsih.c
index 4d8f477..582c390 100644
--- a/drivers/scsi/mpt2sas/mpt2sas_scsih.c
+++ b/drivers/scsi/mpt2sas/mpt2sas_scsih.c
@@ -4258,12 +4258,6 @@ _scsih_sas_volume_add(struct MPT2SAS_ADAPTER *ioc,
 	u16 handle = le16_to_cpu(element->VolDevHandle);
 	int rc;
 
-#if 0 /* RAID_HACKS */
-	if (le32_to_cpu(event_data->Flags) &
-	    MPI2_EVENT_IR_CHANGE_FLAGS_FOREIGN_CONFIG)
-		return;
-#endif
-
 	mpt2sas_config_get_volume_wwid(ioc, handle, &wwid);
 	if (!wwid) {
 		printk(MPT2SAS_ERR_FMT
@@ -4318,12 +4312,6 @@ _scsih_sas_volume_delete(struct MPT2SAS_ADAPTER *ioc,
 	unsigned long flags;
 	struct MPT2SAS_TARGET *sas_target_priv_data;
 
-#if 0 /* RAID_HACKS */
-	if (le32_to_cpu(event_data->Flags) &
-	    MPI2_EVENT_IR_CHANGE_FLAGS_FOREIGN_CONFIG)
-		return;
-#endif
-
 	spin_lock_irqsave(&ioc->raid_device_lock, flags);
 	raid_device = _scsih_raid_device_find_by_handle(ioc, handle);
 	spin_unlock_irqrestore(&ioc->raid_device_lock, flags);
@@ -4436,14 +4424,38 @@ _scsih_sas_pd_add(struct MPT2SAS_ADAPTER *ioc,
 	struct _sas_device *sas_device;
 	unsigned long flags;
 	u16 handle = le16_to_cpu(element->PhysDiskDevHandle);
+	Mpi2ConfigReply_t mpi_reply;
+	Mpi2SasDevicePage0_t sas_device_pg0;
+	u32 ioc_status;
 
 	spin_lock_irqsave(&ioc->sas_device_lock, flags);
 	sas_device = _scsih_sas_device_find_by_handle(ioc, handle);
 	spin_unlock_irqrestore(&ioc->sas_device_lock, flags);
-	if (sas_device)
+	if (sas_device) {
 		sas_device->hidden_raid_component = 1;
-	else
-		_scsih_add_device(ioc, handle, 0, 1);
+		return;
+	}
+
+	if ((mpt2sas_config_get_sas_device_pg0(ioc, &mpi_reply, &sas_device_pg0,
+	    MPI2_SAS_DEVICE_PGAD_FORM_HANDLE, handle))) {
+		printk(MPT2SAS_ERR_FMT "failure at %s:%d/%s()!\n",
+		    ioc->name, __FILE__, __LINE__, __func__);
+		return;
+	}
+
+	ioc_status = le16_to_cpu(mpi_reply.IOCStatus) &
+	    MPI2_IOCSTATUS_MASK;
+	if (ioc_status != MPI2_IOCSTATUS_SUCCESS) {
+		printk(MPT2SAS_ERR_FMT "failure at %s:%d/%s()!\n",
+		    ioc->name, __FILE__, __LINE__, __func__);
+		return;
+	}
+
+	_scsih_link_change(ioc,
+	    le16_to_cpu(sas_device_pg0.ParentDevHandle),
+	    handle, sas_device_pg0.PhyNum, MPI2_SAS_NEG_LINK_RATE_1_5);
+
+	_scsih_add_device(ioc, handle, 0, 1);
 }
 
 #ifdef CONFIG_SCSI_MPT2SAS_LOGGING
@@ -4543,12 +4555,15 @@ _scsih_sas_ir_config_change_event(struct MPT2SAS_ADAPTER *ioc, u8 VF_ID,
 {
 	Mpi2EventIrConfigElement_t *element;
 	int i;
+	u8 foreign_config;
 
 #ifdef CONFIG_SCSI_MPT2SAS_LOGGING
 	if (ioc->logging_level & MPT_DEBUG_EVENT_WORK_TASK)
 		_scsih_sas_ir_config_change_event_debug(ioc, event_data);
 
 #endif
+	foreign_config = (le32_to_cpu(event_data->Flags) &
+	    MPI2_EVENT_IR_CHANGE_FLAGS_FOREIGN_CONFIG) ? 1 : 0;
 
 	element = (Mpi2EventIrConfigElement_t *)&event_data->ConfigElement[0];
 	for (i = 0; i < event_data->NumElements; i++, element++) {
@@ -4556,11 +4571,13 @@ _scsih_sas_ir_config_change_event(struct MPT2SAS_ADAPTER *ioc, u8 VF_ID,
 		switch (element->ReasonCode) {
 		case MPI2_EVENT_IR_CHANGE_RC_VOLUME_CREATED:
 		case MPI2_EVENT_IR_CHANGE_RC_ADDED:
-			_scsih_sas_volume_add(ioc, element);
+			if (!foreign_config)
+				_scsih_sas_volume_add(ioc, element);
 			break;
 		case MPI2_EVENT_IR_CHANGE_RC_VOLUME_DELETED:
 		case MPI2_EVENT_IR_CHANGE_RC_REMOVED:
-			_scsih_sas_volume_delete(ioc, element);
+			if (!foreign_config)
+				_scsih_sas_volume_delete(ioc, element);
 			break;
 		case MPI2_EVENT_IR_CHANGE_RC_PD_CREATED:
 			_scsih_sas_pd_hide(ioc, element);
@@ -4679,6 +4696,9 @@ _scsih_sas_ir_physical_disk_event(struct MPT2SAS_ADAPTER *ioc, u8 VF_ID,
 	u32 state;
 	struct _sas_device *sas_device;
 	unsigned long flags;
+	Mpi2ConfigReply_t mpi_reply;
+	Mpi2SasDevicePage0_t sas_device_pg0;
+	u32 ioc_status;
 
 	if (event_data->ReasonCode != MPI2_EVENT_IR_PHYSDISK_RC_STATE_CHANGED)
 		return;
@@ -4695,22 +4715,40 @@ _scsih_sas_ir_physical_disk_event(struct MPT2SAS_ADAPTER *ioc, u8 VF_ID,
 	spin_unlock_irqrestore(&ioc->sas_device_lock, flags);
 
 	switch (state) {
-#if 0
-	case MPI2_RAID_PD_STATE_OFFLINE:
-		if (sas_device)
-			_scsih_remove_device(ioc, handle);
-		break;
-#endif
 	case MPI2_RAID_PD_STATE_ONLINE:
 	case MPI2_RAID_PD_STATE_DEGRADED:
 	case MPI2_RAID_PD_STATE_REBUILDING:
 	case MPI2_RAID_PD_STATE_OPTIMAL:
-		if (sas_device)
+		if (sas_device) {
 			sas_device->hidden_raid_component = 1;
-		else
-			_scsih_add_device(ioc, handle, 0, 1);
+			return;
+		}
+
+		if ((mpt2sas_config_get_sas_device_pg0(ioc, &mpi_reply,
+		    &sas_device_pg0, MPI2_SAS_DEVICE_PGAD_FORM_HANDLE,
+		    handle))) {
+			printk(MPT2SAS_ERR_FMT "failure at %s:%d/%s()!\n",
+			    ioc->name, __FILE__, __LINE__, __func__);
+			return;
+		}
+
+		ioc_status = le16_to_cpu(mpi_reply.IOCStatus) &
+		    MPI2_IOCSTATUS_MASK;
+		if (ioc_status != MPI2_IOCSTATUS_SUCCESS) {
+			printk(MPT2SAS_ERR_FMT "failure at %s:%d/%s()!\n",
+			    ioc->name, __FILE__, __LINE__, __func__);
+			return;
+		}
+
+		_scsih_link_change(ioc,
+		    le16_to_cpu(sas_device_pg0.ParentDevHandle),
+		    handle, sas_device_pg0.PhyNum, MPI2_SAS_NEG_LINK_RATE_1_5);
+
+		_scsih_add_device(ioc, handle, 0, 1);
+
 		break;
 
+	case MPI2_RAID_PD_STATE_OFFLINE:
 	case MPI2_RAID_PD_STATE_NOT_CONFIGURED:
 	case MPI2_RAID_PD_STATE_NOT_COMPATIBLE:
 	case MPI2_RAID_PD_STATE_HOT_SPARE:
--
To unsubscribe from this list: send the line "unsubscribe linux-scsi" in
the body of a message to majordomo@xxxxxxxxxxxxxxx
More majordomo info at  http://vger.kernel.org/majordomo-info.html

[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]
[Index of Archives]     [SCSI Target Devel]     [Linux SCSI Target Infrastructure]     [Kernel Newbies]     [IDE]     [Security]     [Git]     [Netfilter]     [Bugtraq]     [Yosemite News]     [MIPS Linux]     [ARM Linux]     [Linux Security]     [Linux RAID]     [Linux ATA RAID]     [Linux IIO]     [Samba]     [Device Mapper]