From: Swen Schillig <swen@xxxxxxxxxxxx> The remote port remains in error state even if the connection is re-established. A wrong precondition check was performed on the port status leading to a cancellation of the port reopen. Remove the pre-req check because it's not required and better handled within the ERP. Signed-off-by: Swen Schillig <swen@xxxxxxxxxxxx> Signed-off-by: Christof Schmitt <christof.schmitt@xxxxxxxxxx> --- drivers/s390/scsi/zfcp_fc.c | 5 ----- 1 file changed, 5 deletions(-) --- a/drivers/s390/scsi/zfcp_fc.c 2009-04-17 15:03:37.000000000 +0200 +++ b/drivers/s390/scsi/zfcp_fc.c 2009-04-17 15:03:40.000000000 +0200 @@ -432,11 +432,6 @@ void zfcp_fc_link_test_work(struct work_ container_of(work, struct zfcp_port, test_link_work); int retval; - if (!(atomic_read(&port->status) & ZFCP_STATUS_COMMON_UNBLOCKED)) { - zfcp_port_put(port); - return; /* port erp is running and will update rport status */ - } - zfcp_port_get(port); port->rport_task = RPORT_DEL; zfcp_scsi_rport_work(&port->rport_work); -- To unsubscribe from this list: send the line "unsubscribe linux-scsi" in the body of a message to majordomo@xxxxxxxxxxxxxxx More majordomo info at http://vger.kernel.org/majordomo-info.html