Re: [PATCH v3 0/1] aacraid: Host adapter Adaptec 6405 constantly resets under high io load

[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

 



On Fri, Dec 16, 2022 at 08:44:22PM +0000, Sagar.Biradar@xxxxxxxxxxxxx wrote:
> Konstantin,
> Is it possible for you or someone you know to test on your original test bed with the "msi" set to "1", and post the results?

Hello,

I had lately some exchange with Konstantin about the issue and he
suggested to document my findings on LKML for the benefit of the wider
community. 

I was encountering the same issue with an Adaptec 6405E with 4 connected
disks configured on the controller as "Simple_volume" and further
utilised in a Linux software RAID (mdraid) configuration. My CPU is a
i7-3930K.

I had set "msi" to "2" and the problem persisted. I have not tested
msi=1 but as far as I understand it should have the same effect with
regards to the system hangs.

I have applied Konstantins [PATCH v2 1/2] to a v6.6 line kernel and the
system hangs disappeared. My system has been running for 12 days without
any syslog message indicating a controller problem despite occasional
heavy I/O load.

Please let me know if you require any additional information.

Kind regards,
Dirk.




[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]
[Index of Archives]     [SCSI Target Devel]     [Linux SCSI Target Infrastructure]     [Kernel Newbies]     [IDE]     [Security]     [Git]     [Netfilter]     [Bugtraq]     [Yosemite News]     [MIPS Linux]     [ARM Linux]     [Linux Security]     [Linux RAID]     [Linux ATA RAID]     [Linux IIO]     [Samba]     [Device Mapper]