Re: [PATCH v5 06/28] block: Remember zone capacity when revalidating zones

[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

 



On 4/3/24 01:42, Damien Le Moal wrote:
In preparation for adding zone write plugging, modify
blk_revalidate_disk_zones() to get the capacity of zones of a zoned
block device. This capacity value as a number of 512B sectors is stored
in the gendisk zone_capacity field.

Given that host-managed SMR disks (including zoned UFS drives) and all
known NVMe ZNS devices have the same zone capacity for all zones
blk_revalidate_disk_zones() returns an error if different capacities are
detected for different zones.

This also adds check to verify that the values reported by the device
for zone capacities are correct, that is, that the zone capacity is
never 0, does not exceed the zone size and is equal to the zone size for
conventional zones.

Reviewed-by: Bart Van Assche <bvanassche@xxxxxxx>





[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]
[Index of Archives]     [SCSI Target Devel]     [Linux SCSI Target Infrastructure]     [Kernel Newbies]     [IDE]     [Security]     [Git]     [Netfilter]     [Bugtraq]     [Yosemite News]     [MIPS Linux]     [ARM Linux]     [Linux Security]     [Linux RAID]     [Linux ATA RAID]     [Linux IIO]     [Samba]     [Device Mapper]

  Powered by Linux