Sumit, > Maximum SCSI device queue depth limited to 1024 is not sufficient for > RAID volumes configured behind Broadcom RAID controllers. For a 16 > drives RAID volume with 1024 device QD, per drive 64 IOs(1024/16) can > be issued which is not good enough to achieve performance target. Applied to 5.19/scsi-staging, thanks! -- Martin K. Petersen Oracle Linux Engineering