Re: [PATCH 07/20] scsi: pm8001: Fix command initialization in pm80XX_send_read_log()

[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

 



On 10/02/2022 11:42, Damien Le Moal wrote:
Since the sata_cmd struct is zeroed out before its fields are
initialized, there is no need for using "|=" to initialize the
ncqtag_atap_dir_m field. Using a standard assignment removes the sparse
warning:

warning: invalid assignment: |=

Also, since the ncqtag_atap_dir_m field has type __le32, use
cpu_to_le32() to generate the assigned value.

Fixes: c6b9ef5779c3 ("[SCSI] pm80xx: NCQ error handling changes")
Signed-off-by: Damien Le Moal<damien.lemoal@xxxxxxxxxxxxxxxxxx>

Reviewed-by: John Garry <john.garry@xxxxxxxxxx>



[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]
[Index of Archives]     [SCSI Target Devel]     [Linux SCSI Target Infrastructure]     [Kernel Newbies]     [IDE]     [Security]     [Git]     [Netfilter]     [Bugtraq]     [Yosemite News]     [MIPS Linux]     [ARM Linux]     [Linux Security]     [Linux RAID]     [Linux ATA RAID]     [Linux IIO]     [Samba]     [Device Mapper]