Re: [PATCH 0/2] mpt3sas: Use Firmware Recommended Queue Depth.

[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

 



On Mon, 9 Aug 2021 12:56:37 +0530, Suganath Prabu S wrote:

> Currently mpt3sas driver sets below predefined queue depth for the
> SAS/SATA/NVMe drives.
> SAS	-  254
> SATA	-  32
> NVME	-  128
> IOC Firmware provides the queue depth for each device types through SAS
> IO Unit Page1 for SAS/SATA and PCIe IO Unit Page1 for NVMe devices. If
> the host sets the queue depth greater than the firmware recommended
> queue depth, then IOC places the IO’s above the recommended queue depth
> in an internal pending queue (consuming outstanding
> host-credit/resources and thereby leading to potential starvation to
> other devices) and sends them to the device once IO count drops below
> the recommended queue depth. So, it is better for the driver to set
> the device queue depth provided by the IOC firmware.
> 
> [...]

Applied to 5.15/scsi-queue, thanks!

[1/2] mpt3sas: Use FW recommended device QD
      https://git.kernel.org/mkp/scsi/c/787f2448c236
[2/2] mpt3sas: Update driver version to 39.100.00.00
      https://git.kernel.org/mkp/scsi/c/cdc1767698a2

-- 
Martin K. Petersen	Oracle Linux Engineering



[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]
[Index of Archives]     [SCSI Target Devel]     [Linux SCSI Target Infrastructure]     [Kernel Newbies]     [IDE]     [Security]     [Git]     [Netfilter]     [Bugtraq]     [Yosemite News]     [MIPS Linux]     [ARM Linux]     [Linux Security]     [Linux RAID]     [Linux ATA RAID]     [Linux IIO]     [Samba]     [Device Mapper]