On Friday, January 26, 2007 12:53 PM, Jun'ichi Nomura wrote: > Hi, > > > I have new NEC server with SAS1068 PCI-X Fusion-MPT SAS > > pciid: 1000:0055 > > mptsas form 2.6.20-rc5 don't recognize it ;( > > > > I see that driver support only 1000:0054 and 1000:0058 devices. > > It might be that the device has software RAID feature and changes > device ID based on setup. (1000:0055 when software RAID is enabled > and 1000:0054 or something for normal SAS) > > If so, there is a chance you can disable the software RAID > via BIOS setup utility. > > Thanks, > -- > Jun'ichi Nomura, NEC Corporation of America > You probably want to talk to the megaraid folks and see if the have a driver for that. I didn't submit a device id of 0055 to sourceforge. The only 1068 ids that are clamied by mptsas is 0054 and 0058 which are the pcix and pcie solutions. I notice that 0055 is listed in repository, but it was not me that submitted that. http://pci-ids.ucw.cz/iii/?i=1000 Eric Moore - To unsubscribe from this list: send the line "unsubscribe linux-scsi" in the body of a message to majordomo@xxxxxxxxxxxxxxx More majordomo info at http://vger.kernel.org/majordomo-info.html