On 6/11/2020 10:42 AM, Shyam Sundar wrote:
Seems like this (and a previous email) never made it to the reflector, resending.

The suggestions make sense to me, and I have made most of the recommended changes.
I was looking for some guidance on placements of the sim stats structures.

On May 29, 2020, at 11:53 AM, Shyam Sundar <ssundar@xxxxxxxxxxx> wrote:

James,
      I was thinking of adding a structures for tracking the target FPIN stats.

struct fc_rport_statistics {
uint32_t link_failure_count;
uint32_t loss_of_sync_count;
....
}

under fc_rport:

struct fc_rport {

/* Private (Transport-managed) Attributes */
struct fc_rport_statistics;

      For host FPIN stats (essentially the alarm & warning), was not sure if I should add them to the fc_host_statistics or
define a new structure under the Private Attributes section within the fc_host_attrs/fc_vport.

my initial thought was the same


      In theory, given that the host stats could be updated both via signals and FPIN, one could argue that it would make sense
to maintain it with the current host statistics, but keeping it confined to transport will ensure we have a uniform way of handling
congestion and peer congestion events.

but then I have the same thoughts as well. And the commonization of the parsing and incrementing makes a lot more sense.


     Would appreciate your thoughts there.

Thanks
Shyam


I would put them under the Dynamic attributes area in fc_host_attrs and fc_rport.
fc_host_attrs:
fpin_cn              incremented for each Congestion Notify FPIN
cn_sig_warn     incremented for each congestion warning signal
cn_sig_alarm    incremented for each congestion alarm signal
fpin_dn             incremented for each Delivery Notification FPIN where attached wwpn is local port fpin_li                incremented for each Link Integrity FPIN where attached wwpn is local port

fc_rport:
fpin_dn             incremented for each Delivery Notification FPIN where attached wwpn is the rport fpin_li               incremented for each Link Integrity FPIN where attached wwpn is the rport fpin_pcn           incremented for each Peer Congestion Notify FPIN where attached wwpn is the rport

For the cn_sig_xxx values, the driver would just increment them.
For the fpin_xxx values - we'll augment the fc_host_fpin_rcv routine to parse the fpin and increment the fc_host or fc_rport counter.

-- james





[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]
[Index of Archives]     [SCSI Target Devel]     [Linux SCSI Target Infrastructure]     [Kernel Newbies]     [IDE]     [Security]     [Git]     [Netfilter]     [Bugtraq]     [Yosemite News]     [MIPS Linux]     [ARM Linux]     [Linux Security]     [Linux RAID]     [Linux ATA RAID]     [Linux IIO]     [Samba]     [Device Mapper]