When devm_clk_get() returns an error code, a pairing runtime PM usage counter decrement is needed to keep the counter balanced. Signed-off-by: Dinghao Liu <dinghao.liu@xxxxxxxxxx> --- drivers/scsi/ufs/ti-j721e-ufs.c | 1 + 1 file changed, 1 insertion(+) diff --git a/drivers/scsi/ufs/ti-j721e-ufs.c b/drivers/scsi/ufs/ti-j721e-ufs.c index 5216d228cdd9..f3f212f6f9a9 100644 --- a/drivers/scsi/ufs/ti-j721e-ufs.c +++ b/drivers/scsi/ufs/ti-j721e-ufs.c @@ -39,6 +39,7 @@ static int ti_j721e_ufs_probe(struct platform_device *pdev) clk = devm_clk_get(dev, NULL); if (IS_ERR(clk)) { dev_err(dev, "Cannot claim MPHY clock.\n"); + pm_runtime_put_sync(dev); return PTR_ERR(clk); } clk_rate = clk_get_rate(clk); -- 2.17.1