On Mon, 2020-02-03 at 01:17 -0800, Can Guo wrote: > From: Asutosh Das <asutoshd@xxxxxxxxxxxxxx> > > This sequence change is required to avoid dips in voltage > during boot-up. > > Apparently, this dip is caused because in the original > sequence, the regulators are initialized in lpm mode. > And then when the load is set to high, and more current > is drawn, than is allowed in lpm, the dip is seen. > > Signed-off-by: Asutosh Das <asutoshd@xxxxxxxxxxxxxx> > Signed-off-by: Can Guo <cang@xxxxxxxxxxxxxx> > Reviewed-by: Hongwu Su <hongwus@xxxxxxxxxxxxxx> Reviewed-by: Stanley Chu <stanley.chu@xxxxxxxxxxxx>