For regulators used by UFS, vcc, vccq and vccq2 will have voltage range initialized by ufshcd_populate_vreg(), however other regulators may not have voltage range settings if undefined in dt-bindings. In this case, both "min_uV" and "max_uV" fields in ufs_vreg struct will be zero values and used as new voltage range for voltage configuration in different power modes. Currently this may have no harm because if both "min_uV" and "max_uV" always keep "zero value", regulator_set_voltage() will always bypass such invalid values and return "good" results. However improper values shall be fixed to avoid future potential bug. Simply bypass voltage configuration if voltage range is not defined. Signed-off-by: Stanley Chu <stanley.chu@xxxxxxxxxxxx> --- drivers/scsi/ufs/ufshcd.c | 13 ++++++++----- 1 file changed, 8 insertions(+), 5 deletions(-) diff --git a/drivers/scsi/ufs/ufshcd.c b/drivers/scsi/ufs/ufshcd.c index 8b9a01073d62..4e41fdfd0e53 100644 --- a/drivers/scsi/ufs/ufshcd.c +++ b/drivers/scsi/ufs/ufshcd.c @@ -7024,12 +7024,15 @@ static int ufshcd_config_vreg(struct device *dev, name = vreg->name; if (regulator_count_voltages(reg) > 0) { - min_uV = on ? vreg->min_uV : 0; - ret = regulator_set_voltage(reg, min_uV, vreg->max_uV); - if (ret) { - dev_err(dev, "%s: %s set voltage failed, err=%d\n", + if (vreg->min_uV && vreg->max_uV) { + min_uV = on ? vreg->min_uV : 0; + ret = regulator_set_voltage(reg, min_uV, vreg->max_uV); + if (ret) { + dev_err(dev, + "%s: %s set voltage failed, err=%d\n", __func__, name, ret); - goto out; + goto out; + } } uA_load = on ? vreg->max_uA : 0; -- 2.18.0