> Subject: Re: [PATCH v2] storvsc: Set up correct queue depth values for IDE > devices > > > Long, > > > Can you take a look at the following patch? > > >> > + max_sub_channels = > >> > + (num_cpus - 1) / storvsc_vcpus_per_sub_channel; > > What happens if num_cpus = 1? If num_cpus=1, we don't have any sub channels. The host offers one sub channel for VM with 5 CPUs, after that it offers an additional sub channel every 4 CPUs. The primary channel is always offered. > > -- > Martin K. Petersen Oracle Linux Engineering