On 12/22/2017 06:39 PM, James Bottomley wrote: > On Thu, 2017-12-21 at 12:22 +0100, Hannes Reinecke wrote: >> Some storage array set the 'Embedded enclosure' bit even though >> no LUN is present, causing the first RECEIVE DIAGNOSTIC call to >> be returned with sense code 'LOGICAL UNIT NOT SUPPORTED'. >> This patch skips the annoying 'Failed to get diagnostic page 0x1' >> messages for those cases. > > What disagnostic pages does this thing support? Can you do a receive > diagnostic on page 0 to find out? I suspect a lot of embedded > enclosure services are simple and support page 7 only. If it really > refuses all diagnostic page requests (which would be a gross standards > violation), then it should probably be blacklisted by inquiry string as > unusable. > If a LUN is connected it'll respond to the usual set (0, 1, 2, und 6). Sending a RECEIVE DIAGNOSTIC to page 0 will probably yield the same result (ie being returned with that sense code), but at least we won't try to access the other pages. But anyway, yes, the implementation is dodgy. I'm in contact with the vendor and try to straighten things out. Cheers, Hannes -- Dr. Hannes Reinecke Teamlead Storage & Networking hare@xxxxxxx +49 911 74053 688 SUSE LINUX GmbH, Maxfeldstr. 5, 90409 Nürnberg GF: F. Imendörffer, J. Smithard, J. Guild, D. Upmanyu, G. Norton HRB 21284 (AG Nürnberg)