On 17.10.2016 12:24, Sumit Saxena wrote: > For SRIOV enabled firmware, if there is a OCR(online controller reset) > possibility driver set the convert flag to 1, which is not happening if > there are outstanding commands even after 180 seconds. > As driver does not set convert flag to 1 and still making the OCR to run, > VF(Virtual function) driver is directly writing on to the register > instead of waiting for 30 seconds. Setting convert flag to 1 will cause > VF driver will wait for 30 secs before going for reset. > > CC: stable@xxxxxxxxxxxxxxx > Signed-off-by: Kiran Kumar Kasturi <kiran-kumar.kasturi@xxxxxxxxxxxx> > Signed-off-by: Sumit Saxena <sumit.saxena@xxxxxxxxxxxx> Reviewed-by: Tomas Henzl <thenzl@xxxxxxxxxx> Tomas -- To unsubscribe from this list: send the line "unsubscribe linux-scsi" in the body of a message to majordomo@xxxxxxxxxxxxxxx More majordomo info at http://vger.kernel.org/majordomo-info.html