Low I/O performance of PERC 4/DC on PE2650

[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

 



We use a PERC 4/DC card on a PowerEdge 2650 server. Connected to each SCSI bus is a set of 14 physical disks. Using the Dell Manager utility we create RAID 0 (logical) disk with 4-way stripes i.e 4 physical disks(across the two channels) and 128K block size. Using I/O benchmark applications like IOzone, the maximum throughput obtained is only about 100 MBps. We get lower values for other stripe sizes and block sizes. Shouldn't this be higher, considering that the SCSI bus provides 320 MBps throughput ? Does anyone know how to get better performance?

Thanks.
-Selvi


-
: send the line "unsubscribe linux-scsi" in
the body of a message to majordomo@xxxxxxxxxxxxxxx
More majordomo info at  http://vger.kernel.org/majordomo-info.html

[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]
[Index of Archives]     [SCSI Target Devel]     [Linux SCSI Target Infrastructure]     [Kernel Newbies]     [IDE]     [Security]     [Git]     [Netfilter]     [Bugtraq]     [Yosemite News]     [MIPS Linux]     [ARM Linux]     [Linux Security]     [Linux RAID]     [Linux ATA RAID]     [Linux IIO]     [Samba]     [Device Mapper]
  Powered by Linux