On Fri, Sep 08, 2017 at 06:40:15PM +0200, Krzysztof Kozlowski wrote: > On Thu, Sep 07, 2017 at 06:10:00PM +0200, Bartlomiej Zolnierkiewicz wrote: > > From: Willy Wolff <willy.mh.wolff@xxxxxxxxx> > > > > Odroid XU3/4 boards have thermal sensors per 4 pairs of A7+A15 > > cores but currently there is only one thermal-zone (including > > cooling maps) defined (for the first pair of cores - the first > > core of the A7 cluster and the first core of A15 cluster) so > > i.e. if the task is running on any of A15 cores but the first > > one, such core can reach high temperature without any proper > > cooling action. > > > > Fix it by adding missing thermal-zones definitions. > > > > Also while at it fix the number of steps in cpufreq cooling for > > cpu4 (11 steps for A15 corresponds to 700MHz, for 600MHz 12 steps > > should be used). > > > > Signed-off-by: Willy Wolff <willy.mh.wolff@xxxxxxxxx> > > Cc: Rob Herring <robh+dt@xxxxxxxxxx> > > Cc: Mark Rutland <mark.rutland@xxxxxxx> > > Cc: Russell King <linux@xxxxxxxxxxxxxxx> > > Cc: Kukjin Kim <kgene@xxxxxxxxxx> > > [b.zolnierkie: rewrote patch subject & description + minor fixups] > > Signed-off-by: Bartlomiej Zolnierkiewicz <b.zolnierkie@xxxxxxxxxxx> > > Thanks for taking care of this. I'll take it after merge window. Thanks, applied. Best regards, Krzysztof -- To unsubscribe from this list: send the line "unsubscribe linux-samsung-soc" in the body of a message to majordomo@xxxxxxxxxxxxxxx More majordomo info at http://vger.kernel.org/majordomo-info.html