On 06/16/2016 03:23 PM, Laxman Dewangan wrote: > The clock IP used on the Maxim PMICs max77686 and max77802 are > same. The configuration of clock register is also same except > the number of clocks. > > Define the common DT binding file for the clocks of Maxim PMICs > MAX77686 and MAX77802. For this, remove the separate DT binding > document file for maxim,max77802 and move all information to > maxim,max77686 DT binding document. > > Signed-off-by: Laxman Dewangan <ldewangan@xxxxxxxxxx> > CC: Krzysztof Kozlowski <k.kozlowski@xxxxxxxxxxx> > CC: Javier Martinez Canillas <javier@xxxxxxxxxxxx> > > --- > Changes from V1: > - Rewrite description to remvoe ref to driver. > - Taken care of comment from Krzysztof on the supported clocks and > DT bindings. > --- > .../devicetree/bindings/clock/maxim,max77686.txt | 82 ++++++++++++++++------ > .../devicetree/bindings/clock/maxim,max77802.txt | 44 ------------ > 2 files changed, 59 insertions(+), 67 deletions(-) > delete mode 100644 Documentation/devicetree/bindings/clock/maxim,max77802.txt Reviewed-by: Krzysztof Kozlowski <k.kozlowski@xxxxxxxxxxx> Best regards, Krzysztof -- To unsubscribe from this list: send the line "unsubscribe linux-samsung-soc" in the body of a message to majordomo@xxxxxxxxxxxxxxx More majordomo info at http://vger.kernel.org/majordomo-info.html