On Tue, Feb 24, 2015 at 01:56:54PM +0900, Chanwoo Choi wrote: > This patch fixes the wrong control of PD_DET_EN (power down detection mode) > for Exynos7 because exynos7_tmu_control() always enables the power down detection > mode regardless 'on' parameter. > > Cc: Zhang Rui <rui.zhang@xxxxxxxxx> > Cc: Eduardo Valentin <edubezval@xxxxxxxxx> > Signed-off-by: Chanwoo Choi <cw00.choi@xxxxxxxxxxx> Lukasz, Any objections to this code? BR, Eduardo Valentin > --- > drivers/thermal/samsung/exynos_tmu.c | 3 ++- > 1 file changed, 2 insertions(+), 1 deletion(-) > > diff --git a/drivers/thermal/samsung/exynos_tmu.c b/drivers/thermal/samsung/exynos_tmu.c > index 933cd80..a60f527 100644 > --- a/drivers/thermal/samsung/exynos_tmu.c > +++ b/drivers/thermal/samsung/exynos_tmu.c > @@ -682,6 +682,7 @@ static void exynos7_tmu_control(struct platform_device *pdev, bool on) > > if (on) { > con |= (1 << EXYNOS_TMU_CORE_EN_SHIFT); > + con |= (1 << EXYNOS7_PD_DET_EN_SHIFT); > interrupt_en = > (of_thermal_is_trip_valid(tz, 7) > << EXYNOS7_TMU_INTEN_RISE7_SHIFT) | > @@ -704,9 +705,9 @@ static void exynos7_tmu_control(struct platform_device *pdev, bool on) > interrupt_en << EXYNOS_TMU_INTEN_FALL0_SHIFT; > } else { > con &= ~(1 << EXYNOS_TMU_CORE_EN_SHIFT); > + con &= ~(1 << EXYNOS7_PD_DET_EN_SHIFT); > interrupt_en = 0; /* Disable all interrupts */ > } > - con |= 1 << EXYNOS7_PD_DET_EN_SHIFT; > > writel(interrupt_en, data->base + EXYNOS7_TMU_REG_INTEN); > writel(con, data->base + EXYNOS_TMU_REG_CONTROL); > -- > 1.8.5.5 >
Attachment:
signature.asc
Description: Digital signature