With default config on smdk5250 latest tree throws below message : [ 2.226049] thermal thermal_zone0: critical temperature reached(224 C),shutting down [ 2.227840] reboot: Failed to start orderly shutdown: forcing the issue and hangs randomly because it reads wrong temperature value. I can't figure out any direct relation between LDO10 and TMU from board schematics which I have. So making LDO10 always-on to fix issue for now. Signed-off-by: Yadwinder Singh Brar <yadi.brar@xxxxxxxxxxx> --- arch/arm/boot/dts/exynos5250-smdk5250.dts | 1 + 1 files changed, 1 insertions(+), 0 deletions(-) diff --git a/arch/arm/boot/dts/exynos5250-smdk5250.dts b/arch/arm/boot/dts/exynos5250-smdk5250.dts index bc27cc2..95b5b51 100644 --- a/arch/arm/boot/dts/exynos5250-smdk5250.dts +++ b/arch/arm/boot/dts/exynos5250-smdk5250.dts @@ -190,6 +190,7 @@ regulator-name = "P1.8V_LDO_OUT10"; regulator-min-microvolt = <1800000>; regulator-max-microvolt = <1800000>; + regulator-always-on; }; ldo11_reg: LDO11 { -- 1.7.0.4 -- To unsubscribe from this list: send the line "unsubscribe linux-samsung-soc" in the body of a message to majordomo@xxxxxxxxxxxxxxx More majordomo info at http://vger.kernel.org/majordomo-info.html